Interpret as VREG_CTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0HT_TH0 (DISABLE_VOLTAGE_LIMIT)DISABLE_VOLTAGE_LIMIT 0 (ISOLATE)ISOLATE 0 (UNLOCK)UNLOCK 0 (RST_N)RST_N

Description

Voltage Regulator Control

Fields

HT_TH

high temperature protection threshold regulator power transistors are disabled when junction temperature exceeds threshold 000 - 100C 001 - 105C 010 - 110C 011 - 115C 100 - 120C 101 - 125C 110 - 135C 111 - 150C

DISABLE_VOLTAGE_LIMIT

0=not disabled, 1=enabled

ISOLATE

isolates the VREG control interface 0 - not isolated (default) 1 - isolated

UNLOCK

unlocks the VREG control interface after power up 0 - Locked (default) 1 - Unlocked It cannot be relocked when it is unlocked.

RST_N

returns the regulator to its startup settings 0 - reset 1 - not reset (default)